Tris (tris(hydroxymethyl)aminomethane, also abbreviated as THAM or Trizma), CAS number 77-86-1, is one of the most widely used organic bases for preparing laboratory buffers in biochemistry and molecular biology. Its exceptional buffering capacity in the physiological pH range (7.0 to 9.0) and its compatibility with most enzymatic and cellular systems have made it the industry standard for buffer preparation in molecular biology, chromatography and electrophoresis.
What is Tris: formula and chemical properties
Tris is an aminomethane with three hydroxymethyl groups, molecular formula C₄H₁₁NO₃ (molar mass 121.14 g/mol). It appears as a white, hygroscopic crystalline powder with high water solubility (830 g/L at 20 °C). Its main characteristic is a pKa of 8.06 at 25 °C, which is why it is used as a buffer in the pH range 7.0–9.0. Temperature significantly affects the pH of Tris buffer: the pH decreases by about 0.03 units for every degree Celsius increase in temperature, a variation to consider in biological applications carried out at temperatures other than room temperature.
| Parameter | Value |
|---|---|
| Systematic name | 2-Amino-2-(hydroxymethyl)-1,3-propanediol |
| Abbreviations | Tris, THAM, Trizma |
| Molecular formula | C₄H₁₁NO₃ |
| CAS number | 77-86-1 |
| Molar mass | 121.14 g/mol |
| pKa (25 °C) | 8.06 |
| Useful buffer range | pH 7.0–9.0 |
| Water solubility (20 °C) | 830 g/L |
| Appearance | White crystalline powder |
Tris-HCl buffer: preparation and use
Tris-HCl buffer is prepared by dissolving Tris Base in ultrapure water and adjusting the pH with concentrated hydrochloric acid to the desired value, checked with a calibrated pH meter. The most common working concentration is 10–100 mM. To obtain a pH 8.0 buffer at 25 °C, for example, 12.11 g of Tris Base are dissolved in 800 ml of water, the pH is adjusted to 8.0 with concentrated HCl, and the volume is brought to 1 L with ultrapure water. The buffer can be stored at 4 °C for several months.
TE buffer (Tris-EDTA), one of the most widely used in molecular biology for storing DNA and RNA, is prepared with 10 mM Tris-HCl pH 8.0 and 1 mM EDTA pH 8.0. TBE buffer (Tris-Borate-EDTA) and TAE buffer (Tris-Acetate-EDTA) are used as running buffers in agarose gel electrophoresis for separating nucleic acids.
Tris-HCl buffer recipe table: how much Tris and HCl to use
The table below is a practical starting point for preparing 0.05 M Tris-HCl buffer at 25 °C: mix 50 ml of 0.1 M Tris base with the volume of 0.1 M HCl indicated, then make up to 100 ml with ultrapure water. Because Tris pH is temperature-dependent, always verify and fine-tune the final pH with a calibrated pH meter at the temperature at which the buffer will be used.
| Target pH (25 °C) | 0.1 M HCl to add (ml) |
|---|---|
| 7.2 | 44.7 |
| 7.4 | 42.0 |
| 7.6 | 38.5 |
| 7.8 | 34.5 |
| 8.0 | 29.2 |
| 8.2 | 22.9 |
| 8.4 | 17.2 |
| 8.6 | 12.4 |
| 8.8 | 8.5 |
For a quick single-strength recipe: to make 1 L of 0.1 M Tris-HCl at pH 8.0, dissolve 12.11 g of Tris base (121.14 g/mol) in about 800 ml of ultrapure water, adjust to pH 8.0 with concentrated HCl, then bring the volume to 1 L. For 0.05 M, halve the Tris base to 6.06 g/L; for 1 M stock, use 121.14 g/L.
Temperature correction for Tris buffer pH
Tris has a large temperature coefficient: its pKa decreases by roughly 0.028–0.031 units per degree Celsius. A buffer titrated to a given pH at 25 °C will drift when used at a colder or warmer temperature, so it should be adjusted at the actual working temperature of the protocol. The table shows the approximate real pH of a buffer set to pH 8.0 at 25 °C.
| Working temperature | Approx. actual pH |
|---|---|
| 4 °C | ≈ 8.6 |
| 25 °C | 8.0 (reference) |
| 37 °C | ≈ 7.4 |
Where Tris is used in chemistry and biology
In molecular biology, Tris is the buffering component of almost all standard buffers: cell lysis buffers, binding buffers for ion-exchange chromatography, equilibration buffers for recombinant proteins, and loading buffers for SDS-PAGE. In biochemistry it is used to prepare buffers for enzymatic assays where a neutral or weakly alkaline pH is required, the physiological condition for most enzymes. In clinical diagnostics it is a component of immunochemistry reagents and of standardization solutions for automated systems. In emergency medicine, Tris (THAM) is used intravenously as an alkalinizing agent in cases of severe metabolic acidosis (European Pharmacopoeia, monograph 1100), representing an alternative to sodium bicarbonate in patients with hypercapnia.
Tris Base available in the Pro-Eko catalog
Pro-Eko Srl supplies Tris Base (THAM) powder with certified purity for biochemical and laboratory use. The product comes with a Certificate of Analysis (CoA) and a Safety Data Sheet (SDS) compliant with Regulation (EC) 1907/2006 (REACH), with batch traceability.
Tris Base (THAM) for buffer preparation
Pro-Eko Srl manufactures and supplies Tris Base (THAM, CAS 77-86-1) in certified-purity powder for the preparation of Tris-HCl, TE, TAE and TBE buffers. Each batch comes with a Certificate of Analysis (CoA) and a REACH-compliant Safety Data Sheet (SDS).
Frequently asked questions about Tris in the lab
What is Tris in chemistry?
Tris (tris(hydroxymethyl)aminomethane, CAS 77-86-1) is an organic base with a pKa of 8.06 at 25 °C. In analytical chemistry and biochemistry it is the base component of Tris-HCl, TE, TAE and TBE buffers, used to prepare buffer solutions in the pH range 7.0–9.0.
How many grams of Tris do I need to make a buffer?
For 1 litre of 0.1 M Tris-HCl buffer, dissolve 12.11 g of Tris base (molar mass 121.14 g/mol) in ~800 ml of ultrapure water, adjust the pH with concentrated HCl and bring to 1 L. Scale linearly with molarity: 6.06 g/L for 0.05 M, 121.14 g/L for a 1 M stock. The exact volume of HCl depends on the target pH (see the recipe table above).
What is the difference between Tris Base and Tris-HCl?
Tris Base is the free form of the molecule, with a strongly basic pH in solution (about 10.5 at 1%). Tris-HCl is the hydrochloride salt, with a pH of about 4.5 in solution. To prepare a buffer at physiological pH, one generally starts from Tris Base and acidifies with HCl, or mixes Tris Base and Tris-HCl in proportions defined by the Henderson-Hasselbalch equation.
Why does the pH of Tris buffer vary with temperature?
Tris has a high temperature coefficient: its pKa decreases by about 0.031 units for every degree Celsius. A buffer prepared at pH 8.0 at 25 °C will have a pH of about 8.6 at 4 °C and about 7.4 at 37 °C. This behavior makes it necessary to prepare and measure the pH of Tris buffer at the actual temperature of use of the protocol.
Is Tris compatible with all laboratory techniques?
Tris is not compatible with the Lowry method for protein determination (it interferes with the Folin reagent), nor with certain anionic dyes. It should not be used as a crystallization buffer with magnesium salts at pH above 8.5 due to the risk of precipitation. For NMR techniques, deuterated Tris-d₁₁ should be used. In all other standard biochemical contexts, it is the buffer of choice for pH 7.0–9.0.